KTE-1000AHU
Air Handling Unit Experiment Equipment

Equipment Introduction
-
Blower airflow, current change experiment by system static pressure change
-
Indoor temperature and humidity change and filter, coil pressure loss practice by blower airflow change
-
Heating, humidification experiment
-
Humid-air chart automatic construction and materials analysis
-
DAQ program supply tools with that temperature, humidity (RH, AH), enthalpy, amount of the exchanged heat in each position can be measured in real time, and then saved by Microsoft Excel, so that saved data can be show and analysis by graph
Education Contents
01. Psychrometric Chart drawing using software
02. Measurement analysis pre-cooling and re-cooling of Air handling system
03. Measurement analysis heating and humidification of Air handling system
04. Configuration temperature control sequence circuit for mixture and heating between RA and OA of air handling system and operation
05. Configuration temperature control sequence circuit for mixture and cooling between RA and OA of air handling system and operation
06. Configuration temperature control sequence circuit for mixture and humidification between OA and RA of air handling system and operation
07. Configuration reheating sequence circuit for mixture and preheating, cleaning between OA
and RA of air handling system and operation
08. Configuration sequence circuit for pre-cooling of OA and mixture of RA and then cleaning
and heating of air handling system and operation
09. Configuration sequence circuit for pre-cooling of OA and mixture of RA and then
re-cooling of air handling system and operation
Equipment Characteristics
-
Cycle composition :
-
Fresh air → mixed air → filter 1 → pre heater → pre cooler → humidifier → filter 2 → re heater → re cooler → blower → room → return air
-
Being practicable to operate on manual, temperature and humidity control with connecting by sequence and drawing a psychometric chart, displaying by digital sign data of temperature and pressure
-
Saving of data in every sec by excel file on PC
-
Experiment factors
-
- Cooling & heating capacity of room chamber
- Bypass factor
- Humidification
- Dehumidification
- Psychrometic chart
- Temperature data
- Being saved on every minute until 1,440 min as excel file after click the “SAVE”
System Description

Air duct component



Control panel device component

Mechanical refrigeration device component

Pressure Switch

Structure of DA100 Program
Application of data acquisition equipment
◈Composition of main user interface ◈

(1) Schematic diagram of system show temp, press, in realtime.
(2) Psychometric chart
(3) Data table of temp, humidity, and enthalpy.
(4) Calculation value of performance(BF,CF,q,x)in HX.
◈ Big data auto-storage◈