KTE - 7000PL
RENEWABLE ENERGY PLC TRAINING EQUIPMENT

Equipment Introduction
It is the thread wiring plc control test system for controlling renewable energy generating test system, it can conduct the basic electric circuit practice, national skill certificate circuit practice, and also renewable energy generating system plc control can be programmed and practice, and throughout screen, generating power can be monitored in real time.
Basic sequence education : Connects the thread wire with various new renewable device and banana jack, and by using plc, after programming, it can be operated.
Various circuit sequence design practice : It uses relay (ry), push button switch (pb), select switch (s/sw), toggle switch (t/s), buzzer (bz), power lamp (pl), run lamp (rl), stop lamp (gl), and input and output consists of outside power input part, signal input part, various information save part, cpu output part and communication part, so you can experience various new recycle device control plc.
Safety : DC 24v input power is selected for safety thread wiring test and practice.
Simple wiring practice using banana jack : Not only wiring using wires, but inserting banana jack, easy and simple wiring practice is available.
Features of the Equipment
PLC controlled practice devices, for controlling renewable energy practice devices, can be used to program basic electrical circuit practice and national technical qualification circuits using PLC.
Banana jack cables should be used to shorten wiring time and ensure safe practice.
36pin connectors can be connected and controlled with renewable energy generation systems.
The solar energy generation system
Wind energy generation system
Solar and wind energy hybrid power generation system
Photovoltaic hydrogen fuel cell power generation system
Electrolysis hydrogen fuel cell generation system
It is made in the form of a bag, so it is easy to move and store.
Each device is manufactured in a detachable form and can be easily replaced in the event of a defect.
Training Content
Practice to configure and operation as circuit
Practice to configure switch circuit
Practice to configure relay circuit
Practice to configure of AND circuit
Practice to configure of OR circuit
Practice to configure of NOT circuit
Practice to configure of NAND circuit
Practice to configure of NOR circuit
Practice to configure of lock up circuit
Practice to configure and operation as circuit2
The battery power input circuit training
Using ATS automatic switch circuit for uninterruptible
Practice to configure of commecial electric or battery power selection circuit
Stand-alone inverter circuit configuration training 1
Stand-alone inverter circuit configuration training for Solar street light
Stand-alone inverter circuit configuration training 2
Stand-alone inverter circuit configuration training 3
Hybrid systems and Grid connected inverter circuit configuration1
Hybrid systems and Grid connected inverter circuit configuration2
Stand-alone inverter & Grid connected inverter complex using the system configuration training
Sink Input
When the input signal turns ON, current flows from the switch into the PLC input terminal.
Source Input
When the input signal turns ON, current flows from the PLC input terminal to the switch.
XBC-DR32H Input Circuit Configuration
XBC-DR32H Input Terminal Configuration
Sink Output
When the PLC output contact turns ON, current flows from the load into the output terminal.
Source Output
When the PLC output contact turns ON, current flows from the output terminal to the load.